Manufacturer/company:
Spicher Str. 1a
Köln (Porz-Lind)
Germany
-
-
www.igus.de
Name of test piece/s | E6.29.060J.100.0 – series E6.29 |
---|---|
Project number | IG 2402-1498 |
Created on | 06/18/2025 |
Valid until | 03/28/2030 |
Test type | Particle Emission in Dry-Cleanroom with Pre-aging (ISO 14644-1, -14) |
Classfication | Suitability for air cleanliness class: (ISO-Class):5 |
Particle emission in Dry-Cleanroom with Pre-aging |
|
Aging behavior during continuous operation in Dry-Cleanroom |
|
Test parameter(s) |
Air Cleanliness Class |
Test 1, new (after running-in period, 0 cycles) |
4 |
Test 2, after 2 months (3.2 Mio. cycles) |
4 |
Test 3, after 4 months (5.1 Mio. cycles) |
4 |
Test 4, after 6 months (7.5 Mio. cycles) |
5 |
Test 5, after 8 months (10.0 Mio. cycles) |
5 |
Test 6, after 10 months (15.1 Mio. cycles) |
5 |
Test 7, after 12 months (20.1 Mio. cycles) |
5 |
Overall result |
5 |