Test piece

Name of test piece/s Mipolam Biocontrol Performance
Description Charge number: BC05; batch number: 6511013
Project number GE 2604-1771
Created on 10/01/2026
Valid until 07/28/2031
Test type Hydrogen Peroxide Absorption/Desorption (H2O2), (VDI 2083 Part 20)
Classfication > 5 - ≤ 15 min:fast
Hydrogen Peroxide Absorption/Desorption (H2O2), (VDI 2083 Part 20)

H2O2 hydrogen peroxide absorption/desorption (VDI 2083 Part 20)

Ø k-value

[min]

Standard deviation

[min]

Classification

12.73

1.57

fast


The k-value represents the required decay time to reduce the hydrogen peroxide vapor concentration measured at the beginning of the aeration phase to one tenth of the original concentration. The material classification is based on three separate measurements. The blank value of the test setup is subtracted from each measurement value.

The medium k-value is transferred to the following classification:
• ≤ 5 min: non-absorptive
• > 5 - ≤ 15 min: fast
• > 15 - ≤ 60 min: medium
• > 60 min: slow
• Not determinable: catalytic activity

The k-value can only be used to make a comparative material assessment. Provided the maximum hydrogen peroxide vapor concentration during material exposure is within the defined limit, it does not affect the calculated k-values.