Manufacturer/company:
Bachmühle 2
Mulfingen
No Country
-
-
-
Name of test piece/s | Fan impeller Latamid 66 H2 G/25-V0HF1 |
---|---|
Project number | EB 2403-1502 |
Created on | 03/26/2025 |
Valid until | 04/24/2029 |
Test type | Outgassing Behavior (VOC/SVOC)) |
Classfication |
Fan impeller Latamid 66 H2 G/25-V0HF1: Outgassing behavior VOC/SVOC (ISO 14644-8, -15; ISO 16000-6, -9, -11, -25; VDI 2083 Part 17) |
|||
Contaminant Category (x) |
SERa1) 23 °C [g/m²*s] |
SERa1) 90 °C [g/m²*s] |
ISO‑ACCm Class (x) based on 23° C |
VOC |
< 2.8 x 10-10 |
< 1.7 x 10-9 |
< -9.6 |
SVOC |
< 2.8 x 10-10 |
< 1.7 x 10-9 |
< -9.6 |
Amines |
< 2.8 x 10-10 |
< 1.7 x 10-9 |
-- |
Organophosphates |
< 2.8 x 10-10 |
< 1.7 x 10-9 |
-- |
Siloxanes |
< 2.8 x 10.10 |
7.0 x 10-8 |
-- |
Phthalates |
< 2.8 x 10-10 |
< 1.7 x 10-9 |
-- |