Logo

Manufacturer/company:

BAUER KOMPRESSOREN GmbH

Stäblistrasse 8
München
Germany

Number of projects
2
Number of test pieces
3

Documents

BA 2603-1737_Bescheinigung_02.pdf
Valid until 28.08.2026
BA 2603-1737_certificate_02.pdf
Valid until 28.08.2026
BA 2603-1737_statement_02.pdf
Valid until 28.08.2026
BA 2603-1737_Urkunde_02.pdf
Valid until 28.08.2026

Test piece

Name of test piece/s UVC reaction tube B-VIRUS FREE-702
Description Model number: B-VIRUS FREE XL
Project number BA 2603-1737
Created on 08/28/2026
Valid until Validity date unknown or already passed
Test type UVC radiation intensity
Classfication
UVC radiation intensity


UVC radiation intensity (DIN EN 14255-1)

Inactivation of influenza

Rate

[%]

Required dose [mJ/cm2]

Irradiance

[mJ/cm2*s]

Veff

[l]

tLimit

[s]

Fmax

[m3/h]

90

3.5

61

5.0

0.06

315

99

10.5

0.17

105

99.9

31.5

0.51

35


The following table show the values which were obtained according to literature data from Bianco et. al., 2020[1] for the inactivation of SARS-CoV-2 as a human-pathogenic virus:


UVC radiation intensity (according to Bianco et. al., 2020)

Inactivation of SARS-CoV-2

Rate

[%]

Required dose [mJ/cm2]

Irradiance

[mJ/cm2*s]

Veff

[l]

tLimit

[s]

Fmax

[m3/h]

99.9

3.7

61

5.0

0.06

298

total

kill

16.9

0.28

65